850TrainerLab1

Multiple Choice
Identify the choice that best completes the statement or answers the question.
 

 1. 

The function of a(n) ___________ is to show how components in an electrical system are connected and sometimes where they are located.
a.
specification sheet
c.
NEMA standard
b.
manufacturer’s data sheet
d.
electrical print
 

 2. 

The four primary components of a ladder diagram are power supply, input devices, output devices, and ___________.
a.
conductors
c.
push buttons
b.
contactors
d.
fuses
 

 3. 

A ladder diagram separates input devices to the ___________ side and output devices to the __________ side.
a.
right, left
c.
left, right
b.
top, bottom
d.
bottom, top
 

 4. 

__________ are used on ladder diagrams to identify the line number that contains the output coil’s contact.
a.
Wire numbers
c.
Cross-reference numbers
b.
Terminal numbers
d.
Rung numbers
 

 5. 

Ladder diagrams with multiple pages use _________ and notes to indicate the previous and next pages.
a.
carets
c.
slashes
b.
colors
d.
arrows
 

 6. 

The National Electrical Manufacturer’s Association (NEMA) designates different enclosure types based on _____________.
a.
maximum voltage
c.
enclosure material
b.
environmental conditions
d.
size
 

 7. 

It is good practice to limit the number of connections per terminal block to ________ wires.
a.
one
c.
only two
b.
two or less
d.
three or less
 

 8. 

Terminal blocks are installed inside electrical panels in a certain pattern according to the wiring _________.
a.
voltage rating
c.
length
b.
size
d.
function
 

 9. 

Wire numbers attached to wires in an electrical panel should match the wire numbers shown on the ____________.
a.
Electrical print
c.
Wire manufacturer catalog
b.
Panel door
d.
components
 

 10. 

Wires that run between two panels must enter and exit each panel through _________.
a.
disconnects
c.
circuit breakers
b.
terminal blocks
d.
wireways
 

 11. 

The type of signal that is carried by a wire inside an electrical panel is indicated by the wire __________.
a.
gauge
c.
insulation color
b.
voltage rating
d.
length
 

 12. 

An overcurrent protection device for a motor control circuit operating with a motor FLA of 20 amps should be sized for at least _________ amps.
a.
20
c.
16
b.
25
d.
12.5
 

 13. 

When testing a circuit breaker in the closed position, the resistance between the terminals should measure ___________.
a.
infinite resistance
c.
exactly zero ohms
b.
at least 10 ohms
d.
less than 1 ohms
 

 14. 

When sizing disconnect switches, the current or voltage rating should _________ the source’s current or voltage.
a.
equal or exceed
c.
exactly match
b.
be less than
d.
be 10% higher
 

Matching
 
 
Segment 1 Matching:
a.
line
d.
notes
b.
arrows
e.
ladder
c.
cross-reference
 

 15. 

Most machine electrical prints are in the form of a(n) _________ diagram.
 

 16. 

_________ are used on electrical prints when a device on one line of a print has contacts on other lines.
 

 17. 

A(n) ______ under a number on the right side of a print indicates a normally closed contact on another line.
 

 18. 

______ on a print can tell you what operation is being performed by the components on that line.
 

 19. 

Electrical prints will include _______ at the top or the bottom to indicate that it continues to or is continued from another page.
 
 
Segment 2 Matching
a.
motor power leads
d.
end anchors
b.
control
e.
terminal blocks
c.
DIN rails
 

 20. 

A(n) _______ panel contains devices such as motor starters, control relays, timers and control transformers.
 

 21. 

________ provide a convenient location for numbering the wires in a panel according to the electrical print.
 

 22. 

Larger terminal blocks are used for ________.
 

 23. 

Terminal blocks are most commonly installed on _________.
 

 24. 

Retaining clips or _______ are used to prevent the terminal blocks from slipping.
 
 
Segment 3 Matching
a.
black
d.
starter coils
b.
signal
e.
control panel
c.
identify
 

 25. 

Wire numbers on an electrical print are necessary to ______ the connections within each panel and the connections between panels.
 

 26. 

The color of the wire’s insulation can tell you what type of ______ the wire is carrying.
 

 27. 

Underground power conductors coming into a panel should have insulation with the color of ________.
 

 28. 

Typically, the wires to an operator station come from the _________.
 

 29. 

Wire numbers are usually not shown between _______ and overload contacts, because motor starters usually contain them as a single unit.
 
 
a.
less than 1
d.
62.5
b.
phase
e.
125
c.
circuit breaker
 

 30. 

Overcurrent protection devices for motor control circuits are rated at _______ % of the full load ampere.
 

 31. 

After a(n) _______ is tripped, it can be reset and used again.
 

 32. 

When testing a fuse with a digital multimeter, the measured resistance should indicate _________ ohm(s).
 

 33. 

A disconnect switch for a motor control circuit with an FLA of 50 amps must be sized for at least _______ amps.
 

 34. 

A fusible disconnect switch includes one fuse for each main power_______.
 



 