Multiple Choice Identify the
choice that best completes the statement or answers the question.
|
|
1.
|
The function of a(n) ___________ is to show how components in an electrical
system are connected and sometimes where they are located.
a. | specification sheet | c. | NEMA standard | b. | manufacturer’s data
sheet | d. | electrical
print |
|
|
2.
|
The four primary components of a ladder diagram are power supply, input devices,
output devices, and ___________.
a. | conductors | c. | push buttons | b. | contactors | d. | fuses |
|
|
3.
|
A ladder diagram separates input devices to the ___________ side and output
devices to the __________ side.
a. | right, left | c. | left, right | b. | top, bottom | d. | bottom, top |
|
|
4.
|
__________ are used on ladder diagrams to identify the line number that contains
the output coil’s contact.
a. | Wire numbers | c. | Cross-reference numbers | b. | Terminal
numbers | d. | Rung
numbers |
|
|
5.
|
Ladder diagrams with multiple pages use _________ and notes to indicate the
previous and next pages.
a. | carets | c. | slashes | b. | colors | d. | arrows |
|
|
6.
|
The National Electrical Manufacturer’s Association (NEMA) designates
different enclosure types based on _____________.
a. | maximum voltage | c. | enclosure material | b. | environmental conditions | d. | size |
|
|
7.
|
It is good practice to limit the number of connections per terminal block to
________ wires.
a. | one | c. | only two | b. | two or less | d. | three or less |
|
|
8.
|
Terminal blocks are installed inside electrical panels in a certain pattern
according to the wiring _________.
a. | voltage rating | c. | length | b. | size | d. | function |
|
|
9.
|
Wire numbers attached to wires in an electrical panel should match the wire
numbers shown on the ____________.
a. | Electrical print | c. | Wire manufacturer catalog | b. | Panel
door | d. | components |
|
|
10.
|
Wires that run between two panels must enter and exit each panel through
_________.
a. | disconnects | c. | circuit breakers | b. | terminal blocks | d. | wireways |
|
|
11.
|
The type of signal that is carried by a wire inside an electrical panel is
indicated by the wire __________.
a. | gauge | c. | insulation color | b. | voltage rating | d. | length |
|
|
12.
|
An overcurrent protection device for a motor control circuit operating with a
motor FLA of 20 amps should be sized for at least _________ amps.
|
|
13.
|
When testing a circuit breaker in the closed position, the resistance between
the terminals should measure ___________.
a. | infinite resistance | c. | exactly zero ohms | b. | at least 10 ohms | d. | less than 1
ohms |
|
|
14.
|
When sizing disconnect switches, the current or voltage rating should _________
the source’s current or voltage.
a. | equal or exceed | c. | exactly match | b. | be less than | d. | be 10% higher |
|
Matching
|
|
|
Segment 1 Matching:
a. | line | d. | notes | b. | arrows | e. | ladder | c. | cross-reference |
|
|
15.
|
Most machine electrical prints are in the form of a(n) _________
diagram.
|
|
16.
|
_________ are used on electrical prints when a device on one line of a print
has contacts on other lines.
|
|
17.
|
A(n) ______ under a number on the right side of a print indicates a normally
closed contact on another line.
|
|
18.
|
______ on a print can tell you what operation is being performed by the
components on that line.
|
|
19.
|
Electrical prints will include _______ at the top or the bottom to indicate
that it continues to or is continued from another page.
|
|
|
Segment 2 Matching
a. | motor power leads | d. | end
anchors | b. | control | e. | terminal blocks | c. | DIN rails |
|
|
20.
|
A(n) _______ panel contains devices such as motor starters, control relays,
timers and control transformers.
|
|
21.
|
________ provide a convenient location for numbering the wires in a panel
according to the electrical print.
|
|
22.
|
Larger terminal blocks are used for ________.
|
|
23.
|
Terminal blocks are most commonly installed on _________.
|
|
24.
|
Retaining clips or _______ are used to prevent the terminal blocks from
slipping.
|
|
|
Segment 3 Matching
a. | black | d. | starter
coils | b. | signal | e. | control panel | c. | identify |
|
|
25.
|
Wire numbers on an electrical print are necessary to ______ the connections
within each panel and the connections between panels.
|
|
26.
|
The color of the wire’s insulation can tell you what type of ______ the
wire is carrying.
|
|
27.
|
Underground power conductors coming into a panel should have insulation with
the color of ________.
|
|
28.
|
Typically, the wires to an operator station come from the _________.
|
|
29.
|
Wire numbers are usually not shown between _______ and overload contacts,
because motor starters usually contain them as a single unit.
|
|
|
a. | less than 1 | d. | 62.5 | b. | phase | e. | 125 | c. | circuit
breaker |
|
|
30.
|
Overcurrent protection devices for motor control circuits are rated at _______
% of the full load ampere.
|
|
31.
|
After a(n) _______ is tripped, it can be reset and used again.
|
|
32.
|
When testing a fuse with a digital multimeter, the measured resistance should
indicate _________ ohm(s).
|
|
33.
|
A disconnect switch for a motor control circuit with an FLA of 50 amps must be
sized for at least _______ amps.
|
|
34.
|
A fusible disconnect switch includes one fuse for each main
power_______.
|