True/False Indicate whether the
statement is true or false.
|
|
1.
|
Electronic control is prevalent in all types of industrial manfacturing.
|
|
2.
|
PLC’s monitor output signals and generate input signals.
|
|
3.
|
There are two types of control systems.
|
|
4.
|
Open loop systems use sensors that determine what is happening with the
load.
|
|
5.
|
Response time, accuracy, and precision are of great importance with elctronic
control systems.
|
Multiple Choice Identify the
choice that best completes the statement or answers the question.
|
|
6.
|
The following is an example of a ____________.
a. | PLC | d. | open loop system | b. | Transducer | e. | None of the above | c. | closed loop
system |
|
|
7.
|
The following is and example of a ____________.
a. | closed loop system | d. | deadband eliminator | b. | open loop system | e. | pneumonoultramicropicsilicovolcanoconiosis | c. | mainframe |
|
Completion Complete each
statement.
|
|
8.
|
A PLC is an _____________ computer that has sophisticated input/output
capabilities.
|
|
9.
|
_________ are the interface between the physical components and the
electronics.
|
|
10.
|
The __________ signal is the input that instructs the valve to produce a desired
output.
|
|
11.
|
In ________ loop control, the actual result being produced by the actuator is
read by sensor.
|
|
12.
|
Open and closed loop control are concepts that apply to ______ control system,
not just those found in fluid power.
|
|
13.
|
Solenoids are ____________ that are shifted by electrical current.
|
|
14.
|
Solenoids are also commonly used to shift two-way and three-way directional
_______ valves, as well as some types of pressure control valves.
|
|
15.
|
Hydraulic solenoid valves are usually of the wet ___________ type, which means
that the hydraulic fluid is allowed to circulate through the solenoid case.
|
|
16.
|
Solenoids are often used to actuate _________ valves as well as hydraulic
valves.
|
|
17.
|
Proportional valves are similar to solenoid valves in that they are ____________
controlled.
|
|
18.
|
The most commonly used position transducer for proportional valves is a linear
variable differential ______________ (LVDT).
|
|
19.
|
Spool ________ is the amount that the spool land overlaps the pressure port when
in the closed neutral position.
|
|
20.
|
A servo valve is another type of electronically controlled valve that produces
output proportional to an ___________ input signal.
|
|
21.
|
A more efficient way to control flow and pressure is to control it at the
________: the pump.
|
|
22.
|
In electrohydraulic pump control, the pressure and flow output of the pump are
adjusted to match the _______ requirements.
|
Matching
|
|
|
a. | Double solenoid, three position | d. | Single solenoid | b. | Servo
valve | e. | Proportional
valve | c. | Double solenoid, two position |
|
|
23.
|
|
|
24.
|
|
|
25.
|
|
|
26.
|
|
|
27.
|
|
|
|
a. | Accuracy | c. | Precision | b. | Response time |
|
|
28.
|
The difference in time between when a desired result is commanded and when it
is actually achieved.
|
|
29.
|
A measure of how close the actual result is to the desired result.
|
|
30.
|
The measure of repeatability.
|